Big Tech is poaching energy talent to fuel its AI ambitions

Major technology companies such as Google and Microsoft are expanding hiring beyond just AI specialists to include energy experts, reflecting the growing priority of managing rising power demands tied to artificial intelligence and data center build-outs. According to workforce data, energy-related roles in the tech sector have risen significantly year-over-year, as firms compete for talent who can help build and manage infrastructure and electricity systems critical to supporting AI operations and data center growth. (timesofindia.indiatimes.com)

You can opt for the following specializations

Undergraduate Degrees

  • Electrical Engineering (most common)
    • Specialization: Power Systems, Energy Systems
  • Mechanical Engineering
    • Specialization: Thermal Systems, Energy Conversion
  • Chemical Engineering
    • Specialization: Energy Processes, Batteries, Fuels
  • Civil Engineering
    • Specialization: Energy Infrastructure
  • Environmental Engineering / Environmental Science
    • Focus: Sustainability, energy policy

πŸŽ“ Master’s Degrees (very common for energy experts)

  • M.S. in Electrical Engineering (Power & Energy Systems)
  • M.S. in Energy Systems Engineering
  • M.S. in Renewable Energy
  • M.S. in Sustainable Energy / Clean Energy
  • M.S. in Mechanical Engineering (Energy / Thermal focus)
  • M.S. in Engineering Management (Energy focus)

πŸŽ“ PhD (for research or advanced grid roles)

  • PhD in Electrical Engineering (Power Systems)
  • PhD in Energy Systems / Materials / Battery Science

πŸ“Š Policy & Business-Oriented Paths

  • Economics (Energy Economics)
  • Public Policy (Energy Policy)
  • MBA with focus on Energy, Infrastructure, or Sustainability

🏭 Industry Certifications (often alongside degrees)

  • PE (Professional Engineer – Power/Energy)
  • Certified Energy Manager (CEM)
  • Renewable Energy certifications (solar, wind, storage)

πŸ”‘ For Big Tech Energy Roles

Companies like Google & Microsoft often prefer:

  • Electrical Engineering (Power Systems)
  • Energy Systems / Renewable Energy
  • Energy economics or infrastructure planning

Microsoft works with major US electric grid operator to modernize the Midwest power system

Here’s a short summary of the article from Yahoo Finance:

Microsoft has announced a new β€œcommunity-driven AI plan” aimed at addressing concerns about its expanding network of AI data centers in the U.S. As part of this initiative, President Brad Smith said the company will take steps to make sure its data centers don’t cause local electricity prices to rise. Microsoft plans to pay the full costs associated with its power use and related infrastructure, so those costs aren’t passed on to residents. The broader effort also targets issues around water usage, local jobs, taxes and skills development to reduce community pushback against AI infrastructure growth. (finance.yahoo.com)

Difference between BitLocker and Measurement

1. BitLocker – Encryption & Access Control

Purpose: Protects data at rest.

What it does:

  • BitLocker is a full-disk encryption feature in Windows.
  • It encrypts the entire drive using AES-based encryption.
  • The decryption key is released only if the platform passes integrity checks (via TPM measurements or PIN/password).
  • Prevents data theft if the drive is stolen or accessed offline.

Key point:

BitLocker protects what’s on the disk (data confidentiality).

How TPM is involved:

  • TPM stores a Volume Master Key (VMK) encryption key.
  • On boot, TPM compares PCR (Platform Configuration Register) measurements (firmware, bootloader, etc.) with expected values.
  • If they match, TPM releases the decryption key to Windows to unlock the disk.
  • If not, the user must enter a recovery key β†’ this prevents booting on tampered or different hardware.

2. Measurement – Platform Integrity (TPM PCRs)

Purpose: Protects system trustworthiness.

What it does:

  • Measurement means recording the hash of each boot component (BIOS, Option ROMs, Bootloader, OS Loader, etc.) into TPM PCR registers.
  • These measurements are done by firmware (BIOS/UEFI) and bootloaders.
  • They build a chain of trust from power-on to OS handoff.

Key point:

Measurement protects what’s running (system integrity).

Used for:

  • Secure Boot / Measured Boot
  • Remote Attestation (e.g., verifying system state over a network)
  • Policy decisions β€” like whether TPM will release BitLocker keys.

🧠 BitLocker vs. Measurement (Summary Table)

FeatureBitLockerMeasurement (TPM PCRs)
PurposeDisk encryptionPlatform integrity
ProtectsData on diskBoot-time code & configuration
LayerOS-levelFirmware / TPM-level
Uses TPMTo store/release encryption keyTo store hashes (PCRs)
TriggerDisk accessBoot sequence
PreventsOffline data theftBoot-level tampering
VerificationUnlocks disk only if PCRs matchRecords system state for verification
Depends onTPM & OSTPM & firmware

🧭 Example Scenario:

  1. On boot, BIOS, Bootloader, and OS are measured β†’ hashes stored in PCRs.
  2. TPM compares current PCRs to baseline values.
  3. If they match β†’ TPM releases BitLocker key β†’ disk decrypted β†’ OS loads.
  4. If mismatch β†’ TPM refuses β†’ BitLocker recovery required.

Thus:

Measurement ensures the platform is trusted, and BitLocker uses that trust to release encryption keys.

Next-Generation Firewall (NGFW) with Layer 7 Filtering in Embedded Systems

A Next-Generation Firewall (NGFW) extends beyond traditional packet filtering (Layer 3/4) by providing application-level (Layer 7) visibility and control. In embedded systems β€” such as IoT gateways, industrial controllers, or edge servers β€” integrating NGFW capabilities presents unique challenges due to limited CPU, memory, and power. Layer 7 filtering inspects the application data payload, not just IP/port.
It can:

1. What Layer 7 Filtering Means

Enforce policy based on app, user, or content type β€” e.g. β€œblock social media APIs” or β€œallow only JSON over HTTPS from whitelisted domains.”

Identify protocols like HTTP, MQTT, CoAP, Modbus, OPC-UA, etc.

Detect specific application actions (e.g., login, file upload, API calls).

2. NGFW Core Components for Embedded Systems

To achieve this in a constrained environment, the NGFW must include:

ComponentPurposeLightweight Options
Deep Packet Inspection (DPI) EngineParses protocol layers, identifies appsnDPI, L7-filter, Suricata-lite
Stateful Packet Inspection (SPI)Tracks connection statesNetfilter conntrack (Linux)
Application IdentificationUses pattern matching and heuristicsnDPI, AppID library
Content Filtering / IDSDetects malicious payloadsSnort ruleset subset, Suricata rules
Policy EngineEnforces rules per app/user/deviceCustom rule parser or iptables/nftables extensions
TLS/SSL Inspection (optional)For HTTPS visibilityOpenSSL proxy or embedded MITM TLS proxy


3. Example Embedded Software Stack

A realistic embedded NGFW architecture could look like this:

β”Œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”
β”‚ Management UI / CLI β”‚
β”œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€
β”‚ Policy & Rule Engine β”‚
β”œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€
β”‚ AppID + DPI Engine β”‚
β”‚ (nDPI / custom) β”‚
β”œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€
β”‚ SPI / Connection Table β”‚
β”‚ (conntrack) β”‚
β”œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€
β”‚ Packet I/O (DPDK/eBPF) β”‚
β”œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€
β”‚ Network Drivers / NIC β”‚
β””β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”˜

On Linux-based embedded platforms, this stack could run on:

  • OpenWRT / Yocto Linux
  • ARM-based SoCs (Cortex-A53, NXP Layerscape, NVIDIA Jetson, etc.)
  • DPDK or XDP/eBPF for high-performance packet processing


4. Optimization Techniques
To make NGFW features viable in embedded devices:

Maintain a protocol whitelist to minimize parsing workload

Use zero-copy packet paths (DPDK or AF_XDP)

Offload flow classification to smart NICs (like NVIDIA BlueField)

Implement hardware-assisted encryption (AES-NI, ARM Crypto Extensions)

Employ incremental DPI (scan only first few packets per flow)

5. Example Open Source Projects to Build On

FrameworkUse CaseNotes
nDPILightweight DPI engineC library, used by ntopng
SuricataIDS/IPS with Layer 7 supportCan be trimmed for embedded use
Zeek (Bro)Application traffic analysisToo heavy for small systems, ok for edge
OpenWRT + nftablesBase platform for embedded firewallExtensible with Lua/C modules

6. Example Use Cases

  • Industrial IoT gateway blocking unknown MQTT brokers
  • Edge compute node enforcing API access policies
  • 5G small-cell or MEC node filtering HTTP/REST telemetry
  • Smart camera gateway isolating unauthorized cloud uploads

What is the connectx-7 command to read the transceiver data?

To read transceiver (optics) data such as vendor name, part number, wavelength, or temperature from an NVIDIA ConnectX-7 Ethernet adapter, you can use the mlxlink or mlxconfig tools from the Mellanox/NVIDIA MLNX_OFED or NVIDIA Networking tools package.

πŸ”Ή 1. Using mlxlink (preferred for transceiver info)

sudo mlxlink -d --port --show_media_info

sudo mlxlink -d /dev/mst/mt4125_pciconf0 --port 1 --show_media_info

This shows detailed optics/transceiver information:

  • Transceiver type (QSFP56, OSFP, etc.)
  • Vendor name and part number
  • Serial number
  • Connector type
  • Supported speeds
  • Module temperature, voltage, TX/RX power, etc.

To list available devices:

mst status

πŸ”Ή 2. Using ethtool (basic optics data for Ethernet interfaces)

sudo ethtool -m

sudo ethtool -m ens5f0

Outputs (if supported):

  • Vendor, serial, wavelength
  • RX/TX bias, power, temperature

Note: Some ConnectX-7 drivers (esp. for OSFP/QSFP-DD) restrict access via ethtool, so mlxlink gives fuller info.

πŸ”Ή 3. Using mlxconfig (for configuration and EEPROM access)
sudo mlxconfig -d q

sudo mlxconfig -d -e

mlxconfig is mostly for configuration (e.g., link speed, PCIe settings), not optics monitoring β€” use mlxlink for that purpose.

πŸ”Ή 4. Example Output Snippet

MediaInfo:

Module: 400GBASE-DR4
Vendor: FINISAR CORP
Vendor PN: FTL410QE2C
Serial Number: FTL1234A0001
Temp: 36.23Β°C
Voltage: 3.31V
TX Power: 1.72 dBm
RX Power: 2.01 dBm


how to reload ngnix without restart for a configuration change?

To reload Nginx after making configuration changes without restarting or dropping connections, you can use the following command:

sudo nginx -s reload

Explanation:

  • This command tells the running Nginx master process to gracefully reload its configuration.
  • It does not terminate existing connections.
  • New worker processes are spawned using the new configuration, and the old ones are shut down gracefully after serving ongoing requests.

Alternative (Systemd-managed systems)

If you’re on a system using systemd (most modern Linux distros like Ubuntu, CentOS 7+, Debian, etc.):

sudo systemctl reload nginx

Equivalent behavior β€” reloads configuration without restarting the entire service.

Before reloading β€” test your config:

Always validate the configuration file syntax before reloading:

sudo nginx -t

If it shows:

nginx: configuration file /etc/nginx/nginx.conf test is successful

Then you can safely reload.

Summary

CommandPurpose
sudo nginx -tTest configuration for syntax errors
sudo nginx -s reloadGracefully reload config (no restart)
sudo systemctl reload nginxSame as above, via systemd

Does QSFP112 Throttle?

This was my question today to chatgpt and I thought going forward any questions I ask to chatgpt and its answers are pasted as part of my mentoring session. Please find the answer from chatgpt.

What is QSFP112?

QSFP112 (Quad Small Form-Factor Pluggable 112 Gbps) is the latest generation of pluggable optical/electrical transceivers supporting 4Γ—56 Gbps PAM4 lanes β€” typically for 400G or 800G Ethernet applications.

These modules are defined under the QSFP-DD / QSFP112 MSA and IEEE 802.3ck standards.

Thermal Behavior

QSFP112 modules do not implement throttling in the same sense as CPUs or GPUs, but they do have thermal protection mechanisms built into their firmware and hardware.

Most follow this sequence:

TemperatureBehavior
< 0 Β°C or > 85 Β°C (approx.)Out-of-spec β€” performance not guaranteed
~70 Β°C–80 Β°C (Warning threshold)Module may issue a warning via the DOM (Digital Optical Monitoring) interface or MDIO
> 85 Β°C–90 Β°C (Critical)Module may enter protection mode, reduce laser output, or disable transmitters to avoid damage
> 100 Β°C (Fatal)Hardware-level shutdown, link drop to prevent physical damage

So β€” does QSFP112 throttle?

Not in the dynamic power-throttling sense.

Instead, it may:

  • Assert Alarm or Warning bits in the DOM (Digital Diagnostics Monitoring) registers.
  • Shut down its TX channels if the temperature exceeds the critical threshold.
  • In some vendor designs, reduce laser bias (effectively reducing optical output power) β€” which can appear like β€œthrottling,” but it’s a protective fallback, not adaptive performance scaling.

Summary

FeatureQSFP112 Behavior
Active thermal throttling❌ No
Temperature alarm/warningβœ… Yes
Automatic TX disable on overtempβœ… Yes
Power reduction mode⚠️ Optional (vendor-specific)

Resources

QSFP112-SR4-400G Datasheet