Tag: Mellanox

What is the connectx-7 command to read the transceiver data?

To read transceiver (optics) data such as vendor name, part number, wavelength, or temperature from an NVIDIA ConnectX-7 Ethernet adapter, you can use the mlxlink or mlxconfig tools from the Mellanox/NVIDIA MLNX_OFED or NVIDIA Networking tools package.

🔹 1. Using mlxlink (preferred for transceiver info)

sudo mlxlink -d --port --show_media_info

sudo mlxlink -d /dev/mst/mt4125_pciconf0 --port 1 --show_media_info

This shows detailed optics/transceiver information:

  • Transceiver type (QSFP56, OSFP, etc.)
  • Vendor name and part number
  • Serial number
  • Connector type
  • Supported speeds
  • Module temperature, voltage, TX/RX power, etc.

To list available devices:

mst status

🔹 2. Using ethtool (basic optics data for Ethernet interfaces)

sudo ethtool -m

sudo ethtool -m ens5f0

Outputs (if supported):

  • Vendor, serial, wavelength
  • RX/TX bias, power, temperature

Note: Some ConnectX-7 drivers (esp. for OSFP/QSFP-DD) restrict access via ethtool, so mlxlink gives fuller info.

🔹 3. Using mlxconfig (for configuration and EEPROM access)
sudo mlxconfig -d q

sudo mlxconfig -d -e

mlxconfig is mostly for configuration (e.g., link speed, PCIe settings), not optics monitoring — use mlxlink for that purpose.

🔹 4. Example Output Snippet

MediaInfo:

Module: 400GBASE-DR4
Vendor: FINISAR CORP
Vendor PN: FTL410QE2C
Serial Number: FTL1234A0001
Temp: 36.23°C
Voltage: 3.31V
TX Power: 1.72 dBm
RX Power: 2.01 dBm